1 of 1
Drawings not to Scale
Specifications subject to change
Revision: 11/08/99
TYPE III V-SAT
50 Ohm Coaxial Cable
Catalog #2427K
Plenum: CMP(ETL)c(ETL)
C
ABLE CONSTRUCTION:
Center Conductor
Dielectric
Tape
Braid
Jacket
CENTER CONDUCTOR:
10 AWG Solid Copper (0.106” Nom.)
DIELECTRIC:
Foam FEP
Dia. over Dielectric: 0.285” Nom.
SHIELD:
Tape: NB Aluminum Tape
Braid: 34 AWG Tin/Copper
90% Coverage
Nom. Dia. 0.320”
JACKET:
Kynar
Dia. over Jacket: 0.355” +/- 0.007”
Nominal Jacket Thickness: 0.016”
2”
Minimum Spot: 0.01
ELECTRICAL PROPERTIES:
SPARKER TEST:
5000 VAC
DIELECTRIC STRENGTH: Conductor to Shield: 3000 VDC
CAPACITANCE:
24.0 pF./Ft. Nom.
IMPEDANCE:
50.0 +/- 2.0 Ohms
VELOCITY OF PROPAGATION: 84.0% Nom.
DCR: Conductor:
0.938 Ohms/1000 Ft. Max.
n. (500 thru 1800 MHz) 100% Sweep Tested
MECHANICAL PROPERTIES:
MINIMUM BEND RADIUS:
Loaded: 20 Times Cable OD
Unloaded: 10 Times Cable OD
CABLE TEMP. RATING:
Temp: 125
°
C
SRL: 10dB Mi
ATTENUATION:
dB/100 FT. (NOM.)
@ FREQUENCY MHz
3.70 dB
500 MHz
5.80 dB
1000 MHz
6.90 dB
1300 MHz
8.60 dB
1800 MHz